Panasonic FP7 Series Command Reference Manual page 981

Cpu unit
Hide thumbs Also See for FP7 Series:
Table of Contents

Advertisement

Exam
S3
"WR0,64.64"
ple 3
Device setting, Device division: Global, Device code: WR, Device number: 0, Number of bytes: 64
bytes,
Settings
Number of acquisitions: 64 bytes
Exam
S3
"WL10,128,128"
ple 4
Device setting, Device division: Global, Device code: WL, Device number: 10, Number of bytes:
128 bytes,
Settings
Number of acquisitions: 128 bytes
Operand [S4] setting (UPLOAD operation for a device)
● Specify the starting address of the device area that stores a destination URL, or a character
constant.
● Specify a folder name and file name with its relative path from the home directory of the user
who logs in to the HTTP server.
Operand [S4] setting (DOWNLOAD operation for a device)
● Specify the starting address of the device area that stores the string data that indicates a
source URL, or a character constant.
● Specify a folder name and file name with its relative path from the home directory of the user
who logs in to the HTTP server.
Operand [S4] setting (UPDOWN operation for a device)
● Specify the starting address of the device area that stores the string data that indicates a
destination URL, or a character constant.
● Specify a folder name and file name with its relative path from the home directory of the user
who logs in to the HTTP server.
Flag operations
Name
Description
Set when a value outside the range is specified for the parameter.
To be set when the slot number [S1] specified with UNITSEL is not 100 (built-in ET-LAN).
SR7
To be set when transfer setting numbers are not specified in ascending order.
SR8
To be set when executed in an interrupt program.
(ER)
Set when the number of characters for operand specifying character constant exceeds 256.
To be set when an HTTP server that has not been specified with the destination server setting
instruction or the tool software is specified.
CY
Set when the instruction is the initialization of Ethernet. The detail code set in SD29 is "11:
Ethernet initialization active".
(SR9)
(Note 1)
For details of the error codes stored in the system data SD29, refer to
Registers".
WUME-FP7CPUPGR-12
17.17 HTTPcSET (HTTP Client Transfer Setting)
"20.2 List of System Data
17-93

Advertisement

Table of Contents
loading

Table of Contents