17.4.6 Positioning Control Starting Table Number Setting Area

Set the starting table number of positioning data on each axis at the time of staring positioning
control.
The setting ranges are 1 to 600 for the standard area and 10001 to 10025 for the extended
area.
Unit
memory no.
(Hex)
The starting table number
UM 00100
for the positioning control of
1st axis
The starting table number
UM 00101
for the positioning control of
2nd axis
The starting table number
UM 00102
for the positioning control of
the 3rd axis
The starting table number
UM 00103
for the positioning control of
4th axis
The starting table number
UM 00107
for the positioning control of
the virtual axis
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
17-20
Name
Stores the positioning control
starting table number of the 1st axis
Stores the positioning control
starting table number of the 2nd
axis
Stores the positioning control
starting table number of the 3rd axis
Stores the positioning control
starting table number of the 4th axis
Stores the positioning control
starting table number of the virtual
axis
Description
1
1
1
1
1
Default
Setting range
1 to 600
10001 to
10025
1 to 600
10001 to
10025
1 to 600
10001 to
10025
1 to 600
10001 to
10025
1 to 600
10001 to
10025
Set
unit