17.24 SMTPcSET (Mail Transmission Setting)
Exam
S1
"ID=11,TRIG=STATUS,ERR>RUN"
ple 12
Setting number: 11, Send trigger: PLC status change (When operation continue self-diagnostic
Settings
error is detected.)
Exam
S1
"ID=12,TRIG=STATUS,ERRCLR"
ple 13
Settings
Setting number: 12, Send trigger: PLC status change (When error is cleared.)
Exam
S1
"ID=13,TRIG=STATUS,ERR>STOP,ERR>RUN,ERRCLR"
ple 14
Setting number: 13, Send trigger: PLC status change (When operation stop self-diagnostic error is
Settings
detected.), PLC status change (When operation continue self-diagnostic error is detected.), PLC
status change (When error is cleared.)
Operand [S2] setting
● Specify the starting address of the device area that stores the string data that indicates the
destination group number (string) and the subject of the mail to be sent, or a character
constant.
Setting
Settings
item
Destination group
number
S2
Subject
(Note 1)
Input each setting parameter separated by a comma ",".
(Note 2)
Each parameter cannot be omitted. Specify them in the order of the above table. The order of
keywords cannot be changed.
(Note 3)
Upper and lower case characters can be used for specifying keywords.
(Note 4)
Up to 100 destinations can be set.
Subjects automatically generated
Subject automatically generated (Japanese)
bit on detect (R100)
Interval mail (1minute)
Interval mail (24hour)
Specified Time (Every Minute 0s)
Specified Time (Every Hour 0m0s)
Specified Time (Every Day 17h30m0s)
Specified Time (Every Friday 17h30m00s)
PLC status change (Power On)
17-124
Specify a destination group. Specify a destination group number
for the keyword "GRPNO=".
GRPNO=n1+n2 ... +n8
* Up to eight different group numbers connected with pluses (+)
can be selected at the same time.
Specify a mail subject.
User-specified subject: SUBJECT=xxxxx
Automatically-generated subject: SUBJECTAUTO
* For details of subjects generated automatically, refer to
automatically
generated"".
Subject automatically generated (English)
bit on detect (R100)
Interval mail (1minute)
Interval mail (24hour)
Specified Time (Every Minute 0s)
Specified Time (Every Hour 0m0s)
Specified Time (Every Day 17h30m0s)
Specified Time (Every Friday 17h30m00s)
PLC status change (Power On)
Setting
range
0 to 7
""Subjects
WUME-FP7CPUPGR-12