5.17 LCRD (Specified PB Local Device Read)
5.17 LCRD (Specified PB Local Device Read)
■
Ladder diagram
■
Available operation units (●: Available)
Operatio
bit
n unit
i
■
List of operands
Operand
Description
PBm
Source PB number (Available range: 1 to Max. number of PB)
S
Starting address of source local device
n
Number of read devices (Available range: 1 to 65535)
D
Starting address of readout destination device
■
Available devices (●: Available)
Operan
d
W
W
X
Y
PBm
●
●
S
●
●
n
●
●
D
●
●
(Note 1)
Cannot be specified when the operation unit is 16-bit integer (SS, US).
(Note 2)
Index register (I0 to IE)
■
Outline of operation
● This instruction reads the data for [n] from the area specified by [PBm]:[S] (local device) to
the area specified by [D] and subsequent areas all at once.
● For [S], specify a local device that is in the program block of the PB number specified for
[PBm].