Processing
Example 1) When the operation unit is 16-bit (US, SS)
Example 2) When the operation unit is 32-bit (UL, SL, SF)
Precautions for programming
● In the case of a direct address and index modification address, specify the same device for
[S1] and [S2]. At the same time, specify [S2] to be greater than or equal to [S1].
● The data are transferred by operation unit, ending with the device containing [S2].
Example 1) Device address of [S2] comes to a low word (operation unit = 32 bits)
[S1]...DT2 [S2]...DT6 [D]...DT12
Example 2) Device address of [S2] comes to a high word (operation unit = 32 bits)
[S1]...DT2 [S2]...DT7 [D]...DT12
Flag operations
Name
SR7
WUME-FP7CPUPGR-12
Description
To be set in the case of out-of-range in indirect access (index modification).
5.5 BKMV (Block Transfer)