17.32 EIPMSEND (EIP Message Send)
Example of processing
Example) Performing message communication using the connection 1 of the built-in ET-LAN in
the CPU unit
● During the configuration setting, it is necessary to set the built-in ET-LAN connection and the
EIP scan list.
● The slot number for the built-in ET-LAN needs to be specified to be "100".
1. First, using the UNITSEL instruction, specify "100" as the slop number for the built-in ET-
LAN (S1 = U100), and user connection 1 (S2 = U1).
UNITSEL U100 U1
2. Set the destination data using the EIPMSATT instruction.
EIPMSATT DT100
3. Create a value to be set in the message body data using the CIPMSET instruction.
CIPMSET DT200
4. Set the message body data using the EIPMBODY instruction.
EIPMBODY DT500
5. Perform message communication using the EIPMSEND instruction. Received data is
stored in D1 and execution results are stored in D2.
EIPMSEND DT1000 DT2000
Results produced when message communication is completed normally
6.
DT1000
DT1001
DT1002
DT1003
DT2000
17-160
S1
S2
S
U5
DT500
S1
Example 1
D
S
D1
D2
U6 (No. of bytes)
H00
H00
H00
H0
Execution result
Received data size
Received data
H8E
H00
HE
WUME-FP7CPUPGR-12