Panasonic FP7 Series Command Reference Manual page 991

Cpu unit
Hide thumbs Also See for FP7 Series:
Table of Contents

Advertisement

● After this instruction is executed, the PLC operates as shown in the following table.
Conditions
The power supply for the PLC is switched from OFF to ON.
The PLC is changed to
PROG mode.
● This instruction can be executed when the Ethernet initialization active flag (X61) is OFF. As
an execution condition of the instruction, insert a program that checks the status of the flag
(X61). If this instruction is executed when the flag (X61) is ON, the system relay SR9 (carry
flag CY) is set and the instruction is terminated without being executed.
● When the instruction is completed successfully, the system relay SR9 (carry flag CY) and the
system data register SD29 (Ethernet communication error code) are cleared.
Precautions for programming
● Insert the UNITSEL instruction immediately before this instruction and specify the unit (built-
in ET-LAN in the CPU unit) and the connection number.
● Make the event mail setting before executing the instruction.
● This instruction is not available in interrupt programs.
Operand [S1] setting
● Specify the starting address of the device area that stores the string data that indicates a
setting number (string) and a send trigger, or a character constant.
Setting item
Settings
Setting
S1
number
Operand [S2] setting
● Specify the device address where stores the text is stored.
● When "IDx" is specified for [S1], the maximum size of the text is 4096 bytes. An operation
error occurs when it exceeds 4096 bytes.
WUME-FP7CPUPGR-12
Changes to RUN mode without rewriting the
configuration.
Changes to RUN mode after rewriting the
configuration.
Specify a setting number. Event mail send setting number: Idx
17.20 SMTPcBDY (Mail Text Setting)
Operation
Setting using the
configuration
Setting using instructions
Setting using the
configuration
Setting
range
0 to 15
17-103