17.12 FTPcSET (FTP Client Transfer Setting)
Setting
Settings
item
Line feed
position
(Note 1)
Input each source device setting parameter separated by a comma ",".
(Note 2)
Specify the operation setting parameters in the order of the above table.
(Note 3)
When omitting "conversion method" and subsequent items, the conversion method is set to 16-bit
binary and the line feed position is set to 0 (output the end of file only).
(Note 4)
When omitting "Line feed position", it is set to 0: Output the end of file only.
Setting example
Exam
S3
"WX16,32,BIN1w,0"
ple 1
Device setting, Device division: Global, Device code: WX, Device No.: 16
Settings
Number of transferred data: 32 (32 words), Conversion method: Unconverted 16-bit binary, Line
feed position: Output the end of file only
Exam
S3
"DT123456,250,SS,10"
ple 2
Device setting, Device division: Global, Device code: DT, Device No.: 123456
Settings
No. of transferred data: 250 points (250 words), Conversion method: 16-bit signed decimal, Line
feed position: Output by 10 data
Exam
S3
"WR0,16,DF"
ple 3
Device setting, Device division: Global, Device code: WR, Device No.: 0
Settings
No. of transferred data: 16 points (64 words), Conversion method: 64-bit double-precision floating
point, Line feed position: Output the end of file only
Exam
S3
"WL10,128"
ple 4
17-64
Parameter
BIN1w
Unconverted 16-bit binary
US
16-bit unsigned decimal
SS
16-bit signed decimal
UL
32-bit unsigned decimal
SL
32-bit signed decimal
32-bit single-precision floating
SF
point
64-bit double-precision floating
DF
point
HEX1w
16bitHEX
HEX2w
32bitHEX
HEX4w
64bitHEX
ASCII character (Output
ASCII
enclosed with "")
Specify line feed position.
0: Output the end of file only
n: Output by n data
Extension (Saving
format)
.BIN (binary data)
.CSV
(comma-separated text)
WUME-FP7CPUPGR-12
Setting
range
0 to 255