12.8 SUMMER (Daylight Saving Time Acquisition)
Setting example
When the daylight saving time period is from 02:00 on March 8 to 01:59 on November 1, and 60
minutes is specified for the time difference
[S1]...DT0 [S2]...DT10 [S3]...DT20 [D]...DT100
[S1] (Time to start daylight saving time)
[S2] (Time to end daylight saving time)
[S3] (Time difference: in minutes)
Example 1) When the actual time is 01:23:45 on August 31
Because the time is within the specified period, the clock data is corrected and stored.
Descripti
on
SD50
Year
SD51
Month
SD52
Day
SD53
Hours
SD54
Minutes
SD55
Seconds
Day of
SD56
the week
Example 2) When the actual time is 06:07:08 on November 20
Because the time is outside of the specified period, the data is not corrected.
Descripti
on
SD50
Year
SD51
Month
SD52
Day
SD53
Hours
SD54
Minutes
12-18
DT0
DT1
DT2
DT3
DT10
DT11
DT12
DT13
DT20
Value
15
8
31
1
23
45
1
Value
15
11
20
6
7
Descripti
Value
on
Month
3
Day
8
Hours
2
Minutes
0
Month
11
Day
1
Hours
1
Minutes
59
Time
60
difference
Descripti
on
DT100
flag
DT101
Year
DT102
Month
DT103
Day
DT104
Hours
DT105
Minutes
DT106
Seconds
Day of
DT107
the week
Descripti
on
DT100
flag
DT101
Year
DT102
Month
DT103
Day
Value
1
(Enabled)
15
8
31
2
23
45
1
Value
0
(Disabled
)
15
11
20