Specification of control data [N]
15
1211
n:
・・・・
nH (Specify the result
output start bit)
Bit 0: H0
Bit 15: HF
Conversion example
Data to be converted (16
bits)
0000 0000 0000 0001
0000 0000 0000 0010
0000 0000 0000 0100
0000 0000 0000 1000
0000 0000 0001 0000
0000 0000 0010 0000
0000 0000 0100 0000
0000 0000 1000 0000
Specification of nL and length of result
Value of nL
1
2
3
4
WUME-FP7CPUPGR-12
8 7
4 3
0000
0000
・・・・
nL (Specify the conversion-
enabled bit length)
Encoding result
0000
0001
0010
0011
0100
0101
0110
0111
Effective bit length for
conversion
2
4
8 (1 byte)
16 (1 byte)
0
Ignore the bits indicated with '・'.
2
bits: H1
1
2
bits: H8
8
Data to be converted (16
bits)
0000 0001 0000 0000
0000 0010 0000 0000
0000 0100 0000 0000
0000 1000 0000 0000
0001 0000 0000 0000
0010 0000 0000 0000
0100 0000 0000 0000
1000 0000 0000 0000
Value of nL
5
6
7
8
7.9 ENCO (Encoding)
Encoding result
1000
1001
1010
1011
1100
1101
1110
1111
Effective bit length for
conversion
32 (2 byte)
64 (4 byte)
128 (8 byte)
256 (16 byte)
7-21