Advertisement

Flag operations
Name
Description
To be set when an item other than "IDx" or "ALL" is specified for the control target [S1]. (x: 0 to
15)
To be set when a transfer setting that has not been specified with the transfer setting instruction
or the tool software is specified.
SR7
To be set when an item other than "ENABLE", "DISABLE" or "CANCEL" is specified for the
SR8
control content [S2].
(ER)
To be set when the slot number [S1] specified with UNITSEL is not 100 (built-in ET-LAN).
Set when executed in an interrupt program.
Set when the number of characters for operand specifying character constant exceeds 256.
CY
Set when the instruction is the initialization of Ethernet. The detail code that is set in SD29 is "11:
Ethernet initialization active".
(SR9)
(Note 1)
For details of the error codes stored in the system data SD29, refer to
Registers".
WUME-FP7CPUPGR-12
17.19 HTTPcCTL (HTTP Client Transfer Control)
"20.2 List of System Data
17-101