Panasonic FP7 Series Command Reference Manual page 1013

Cpu unit
Hide thumbs Also See for FP7 Series:
Table of Contents

Advertisement

Subject automatically generated (Japanese)
PLC status change (Prog > Run)
PLC status change (Run > Prog)
PLC status change (Operation stop error)
PLC status change (Operation continuous error)
PLC status change (Error release)
SMTPcREQ command
(Note 1)
When multiple "PLC status change" settings have been specified as send triggers, the subject
automatically generated is the PLC status change that is actually detected.
(Note 2)
The language used for subjects automatically generated is specified in the mail server setting.
Setting example
Exam
S2
"GRPNO=0,SUBJECT=Time Notify Mail"
ple 1
Settings
Destination group number: 0, Subject: User-specified subject "Time Notify Mail"
Exam
S2
"GRPNO=1+3+4+7,SUBJECT= Cyclic Notify Mail"
ple 2
Settings
Destination group numbers: 1, 3, 4, 7, Subject: User-specified subject "Cyclic Notify Mail"
Exam
S2
"GRPNO=0+1+2+3+4+5+6+7,SUBJECTAUTO"
ple 3
Settings
Destination group numbers: 0 to 7, Subject: Automatically generated
Operand [S3] setting
Specify the starting address of the device area that stores the string data that indicates the
setting of the text of the mail to be sent, or a character constant.
Setting
Settings
item
Mail text
Character
S3
count
(counted as
one-byte
characters)
Operand [S4] setting
● Specify the starting address of the device area that stores the string data that indicates the
text auto addition setting and the attached data specification of the mail to be sent, or a
character constant.
Setting
Settings
item
Event mail
S4
setting
WUME-FP7CPUPGR-12
17.24 SMTPcSET (Mail Transmission Setting)
Specify the starting address of the device area that stores the setting of the text
of the mail to be sent, or a character constant.
Maximum 4096 characters for CPU units Ver.4.1 or later, and Ver.3.4 to Ver.3.x.
Maximum 256 characters for CPU units that are other than the above.
Specify whether to add event transfer information after a mail text specified by
user or not.
INFO=NON: Not add automatically.
INFO=ADD: Add automatically.
Subject automatically generated (English)
PLC status change (Prog > Run)
PLC status change (Run > Prog)
PLC status change (Operation stop error)
PLC status change (Operation continuous error)
PLC status change (Error release)
SMTPcREQ command
17-125

Advertisement

Table of Contents
loading