Panasonic FP7 Series Command Reference Manual page 479

Cpu unit
Hide thumbs Also See for FP7 Series:
Table of Contents

Advertisement

[S2]
Operation unit: 16 bits
(1-word data)
[S2+1]
[S2+2]
[S2+n-1]
[S2+n]
[S2+n+1]
[S2+n+2]
[S2+2n-1]
[S2+2n]
Precautions for programming
● For data in the data table [S2], ensure that Xn-1 is smaller than Xn.
● When X([S1]) is smaller than x1 ], Y([D]) equals y1.
● When X([S1]) is larger than xn, Y([D]) equals yn.
● The maximum value for [n] that indicates the number of data in the data table [S2] is 256.
Flag operations
Name
SR7
SR8
(ER)
WUME-FP7CPUPGR-12
n
Number for the data table (Available range: 2 to 256)
Operation unit: 32 bits
[S2+1]
x1
[S2+2]
x2
[S2+3]
[S2+4]
x1 to xn
xn-1
[S2+2n-1]
xn
[S2+2n]
[S2+2n+1]
y1
[S2+2n+2]
y2
[S2+2n+3]
[S2+2n+4]
y1 to yn
yn-1
[S2+4n-1]
yn
[S2+4n]
Description
To be set in the case of out-of-range in indirect access (index modification).
To be set when [n] which indicates the number of data in the data table [S2] is smaller than 2
or larger than 256.
To be set when data in the data table [S2] exceeds the area.
To be set when Xn is not in ascending order.
(2-word data)
x1
x2
x1 to xn
xn
y1
y2
y1 to yn
yn
10.7 SCAL (Linearization)
Operation unit: 64 bits
(4-word data)
[S2+1]
[S2+2]
x1
[S2+3]
[S2+4]
[S2+4n-3]
[S2+4n-2]
xn
[S2+4n-1]
[S2+4n]
[S2+4n+1]
[S2+4n+2]
y1
[S2+4n+3]
[S2+4n+4]
[S2+8n-3]
[S2+8n-2]
yn
[S2+8n-1]
[S2+8n]
x1 to xn
y1 to yn
10-29

Advertisement

Table of Contents
loading

Table of Contents