Panasonic FP7 Series Command Reference Manual page 948

Cpu unit
Hide thumbs Also See for FP7 Series:
Table of Contents

Advertisement

17.12 FTPcSET (FTP Client Transfer Setting)
Operan
d
W
W
X
Y
S3
S4
Outline of operation
● This instruction configures the FTP client transfer settings (0 to 15).
● Before executing this instruction, use the
Setting)"
instruction or the programming tool software "FPWIN GR7" to configure the settings
of the destination server.
Processing
● The FTP client transfer settings of [S2] to [S4] are stored in the transfer setting area that is
specified by [S1].
● The instruction can be executed when the transfer request relays of the FTPc control relay
and the FTPc logging/trace control relay are OFF (0: No request). As an execution condition
of the instruction, insert a program that checks the state of the transfer request relay. The
states of the transfer request relay and the logging transfer request relay can be read with
the ETSTAT instruction. Store the state that is read in a device such as an internal relay. An
operation error occurs if the instruction is executed when one of the transfer request relays is
ON.
● After this instruction is executed, the PLC operates as shown in the following table.
Conditions
The power supply for the PLC is switched from OFF to ON.
The PLC is changed to
PROG mode.
● Data is actually sent to files or acquired from files when the FTP client transfer request
(FTPcREQ) instruction is executed after the completion of the FTP client transfer settings.
● This instruction can be executed when the Ethernet initialization active flag (X61) is OFF. As
an execution condition of the instruction, insert a program that checks the status of the flag
(X61). If this instruction is executed when the flag (X61) is ON, the system relay SR9 (carry
flag CY) is set and the instruction is terminated without being executed.
● When the instruction is completed successfully, the system relay SR9 (carry flag CY) and the
system data register SD29 (Ethernet communication error code) are cleared.
Precautions for programming
● Insert the UNITSEL instruction immediately before this instruction and specify the unit (built-
in ET-LAN in the CPU unit) and the connection number.
● For [S1] to [S4], specify the starting address of the device area that stores the string data
that indicates the set parameters, or a character constant. When specifying a device area for
17-60
16-Bit device:
W
W
W
S
D
L
R
L
S
D
T
D
Changes to RUN mode without rewriting the
configuration.
Changes to RUN mode after rewriting the
configuration.
32-Bit
device:
TS
TE
U
W
WI
IX
C
C
M
O
S
E
"17.11 FTPcSV (FTP Client Connected Server
Real
St
Integer
numbe
rin
r
g
D
K
H
SF
" "
F
Operation
Setting using the
configuration
Setting using instructions
Setting using the
configuration
WUME-FP7CPUPGR-12
Index
modifie
r

Advertisement

Table of Contents
loading

Table of Contents