Panasonic FP7 Series Command Reference Manual page 923

Cpu unit
Hide thumbs Also See for FP7 Series:
Table of Contents

Advertisement

Setting
Settings
item
(Essential)
Communication
method setting
(Essential)
(Note 1)
For operation settings, input each setting parameter separated by a comma ",".
(Note 2)
Both upper and lower cases can be used for specifying keywords.
(Note 3)
The operation setting parameters cannot be omitted.
(Note 4)
There is the following difference between high-level instructions and configuration data when UDP is
specified for the communication method. Although the open method (server/client) setting is not
available for configuration data, it must be specified either server or client for high-level instructions.
Specify SV for using it as slave connection, and specify CL for using it as master connection.
(Note 5)
General-purpose communication (with large capacity reception) is available for the CPU units
CPS4R* / CPS3R*.
Setting example
Examp
S1
"MEWCOM,OPTAV,CL,AUTO,TCP"
le 1
Operating mode setting: MEWCOM, Option setting: Option available
Settings
Open type (Server/Client): Client, Open type (Automatic/Manual): Open automatically,
Communication type: TCP/IP
Examp
S1
"MODBUS,OPTNAV,SV,MANU,UDP"
le 2
Operation mode setting: MODBUS, Option setting: Option not available, Open method (Server/
Settings
Client): Server (any partner), Open method (Automatic/Manual): Not open automatically,
Communication method: UDP/IP
Examp
S1
"GP,OPTNAV,SV,AUTO,UDP"
le 3
Operation mode setting: GP, Option setting: Option not available Open method (Server/Client):
Settings
Server (any partner), Open method (Automatic/Manual): Open automatically, Communication
method: UDP/IP
Examp
S1
"GP_LARGE,OPTAV,SV,MANU,TCP"
le 4
Operation mode setting: General-purpose communication (large capacity general-purpose
reception), Option setting: Add no special header
Settings
Open type (server/client): Server connection (any partner)
Open method (Automatic/Manual): Not open automatically, Communication method: TCP/IP
Special keyword of operand [S1] setting
Special keyword
INITIAL
Setting example
Examp
S1
"INITIAL"
le
WUME-FP7CPUPGR-12
17.6 CONSET (User Connection Setting)
Specify communication method (TCP/UDP).
TCP: TCP/IP setting, UDP: UDP/IP setting
* An operation error occurs if UDP is specified when GP_LARGE is specified for
the operation mode setting.
Description
Set an initial value.
17-35

Advertisement

Table of Contents
loading