(1) Acquiring CIP receive header information from its start
[S1]... DT0 [S2]... H4 [D1]... DT100 [D2]... DT1000
S2: Acquired data format
Value
S2
0004H
Operation result
S1: CIP message receive data
Value
DT0
000DH
DT1
00CBH
DT2
0000H
DT3
0001H
DT4
02H
41H (A)
DT5
DT6
34H
DT7
ffH
Offset position after updating
Value
DT0
DT1 1
DT2 3
DT3 5
DT4 7
DT5 9
DT6 B
DT7 D
WUME-FP7CPUPGR-12
D1: Offset position
Value
DT100
0000H
Acquiring data equivalent to 4 bytes
31H (1)
42H (B)
12H
CIP receive data
0
2
4
1st data
6
8
2nd data
A
C
3rd data
17.34 CIPMGET (CIP Message Data Getting)
D2: Acquired data storage destination
DT1000
DT1001
Value
0000H
ffffH
D1: Offset position
Value
DT100
0000H→0004H
D2: Acquired data
Value
DT1000 00CBH
DT1001 0000H