17.38 EIP_OT (EtherNet/IP Output Refresh)
Example 2) When performing the output refresh for the send buffer of the
connection number 5 of the node number 2 (Abnormal end)
[S1]... U2 [S2]... U5 [D]... DT100
● EtherNet/IP configuration setting
Setting item
Node number
Connection
Output Information (O>T)
Device Allocation
Value
LD100
LD101
2233h
LD102
4455h
LD103
LD104
8899h
LD105
AABBh
LD106
CCDDh
LD107
EEFFh
LD108
(Note 1)
Send buffers to which devices are allocated
Flag operations
Name
SR7
SR8
(ER)
17-194
Settings
2
5
LD101 to LD102
LD104 to LD107
Send buffer
x
x
x
x
x
x
Description
To be set when the unit specified by UNITSEL is not the built-in ET-LAN.
To be set when the EtherNet/IP function is set to Not Use in the Ethernet unit configuration.
To be set in case of out-of-range values in indirect access (index modification).
Set when a value outside the range is specified for the parameter.
To be set when the I/O map, node, or connection that is specified by [S1] or [S2] does not
exist.
Use this instruction only for the connections in which the refresh method of the EtherNet/IP
setting is set to Instruction. An operation error occurs when the connection that other refresh
method other than that has been specified is specified.
To be set when the connection for which the amount of output data is 0 is specified.
To be set when the connection for which the number of refreshed data is 0 is specified.
Value
0
DT10
1
2
AABBh
*
3
CCDDh
*
4
5
AABBh
*
6
CCDDh
*
7
EEFFh
*
8
1122h
*
Value
1
WUME-FP7CPUPGR-12