Installing the MX2010 Air Baffle

To install the upper air baffle—MX2000-UPR-BAFFLE-A:
1. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to
one of the ESD points on the chassis.
2. Ensure that the air baffle louvers are closed.
3. Close the upper fan tray access door.
4. Align the holes on the air baffle with the holes located on either side of the upper fan tray access door,
(see
Figure 178 on page
5. Tighten the four captive screws to secure the air baffle to the upper fan tray access door.
6. Open the air baffle louvers to direct the exhaust air away from the router. To direct exhaust air away
from the router, the louvers on the air baffle must be set to a 10-degree fixed upward tilt with respect
to the horizontal.
Figure 178: Installing the Air Baffle