Problem
Description: A MIC LED lit red indicates a problem with the MIC.
Solution
To troubleshoot a MIC:
1. Check the status of each port on a MIC by looking at the LED located on the MIC faceplate. For
information about the meaning of LED states on different MICs, see the
Reference
2. Check the status of a MIC by issuing the show chassis fpc pic-status CLI command. The MIC slots in
the MPC are labeled PIC 0/1 and PIC 2/3, top to bottom:
user@host> show chassis fpc pic-status
Slot 0
Online
PIC 0
Online
PIC 1
Online
PIC 2
Online
PIC 3
Online
Slot 1
Online
PIC 2
Online
PIC 3
Online
Slot 2
Online
PIC 0
Online
PIC 1
Online
PIC 2
Online
Slot 9
Online
PIC 0
Online
PIC 1
Online
PIC 2
Online
PIC 3
Online
For further description of the command output, see the