Installing Mx2000 Router Dc Power Supply Modules (240 V China) - Juniper MX2010 Hardware Manual

Universal routing platform
Hide thumbs Also See for MX2010:
Table of Contents

Advertisement

5. Turn on the power switch to the on (|) position.
6. Verify that the PWR OK LED is lit steadily green.
Figure 168: Installing a DC Power Supply Module
D
RELATED DOCUMENTATION
MX2010 DC Power Supply Module (-48 V) Description | 116
Removing an MX2010 DC Power Supply Module (-48 V) | 475

Installing MX2000 Router DC Power Supply Modules (240 V China)

To install an MX2000 DC PSM (240 V China):
1. Verify that the power switches on all PSMs are in the off (O) position.
2. On the PSM, slide the plastic cover away from the input mode switch to expose the dual DIP switches.
Move the input mode DIP switch 0 (left switch) to the ON position for the bottom feed INP0 (expected
to be connected), and DIP switch 1 (right switch) to the ON position for the top feed INP1 (expected
to be connected). If both DIP switches 0 and 1 are turned to the ON position, then both top and bottom
feeds are expected to be connected, (see
In addition, a PSM failure triggers the alarm LED on the craft interface.
Figure 169 on page
377).