Suzuki XL7 2007 Service Manual page 1519

Jc636
Hide thumbs Also See for XL7 2007:
Table of Contents

Advertisement

Scan Tool Data List - Automatic Transaxle - AF33-5
The values below represent a typical display recorded from a properly functioning system.
NOTE
Do not use a scan tool that displays faulty data. Report the condition to the scan tool manufacturer.
The use of a faulty scan tool can result in misdiagnosis and the unnecessary replacement of parts.
Only the parameters listed below are used in this manual for diagnosing. If a scan tool displays other parameters, the
values are not recommended.
Scan tool values below were recorded under the following conditions:
• Engine at idle
• Upper radiator hose hot
• Closed throttle
• Transmission in Park
• Closed Loop operation
• Accessories OFF
• Brake pedal not applied
Scan Tool Parameter
TP Angle
Battery Voltage
Brake Switch
Commanded Gear
Cruise
ECT
Engine Speed
Engine Torque
Gear Ratio
Ignition Voltage
Last 1-2 Shift Status
Last 2-1 Shift Status
Last 2-3 Shift Status
Last 2-4 Shift Status
Last 3-2 Shift Status
Last 3-4 Shift Status
Last 4-2 Shift Status
Last 4-3 Shift Status
Last 4-5 Shift Status
Last 5-4 Shift Status
Line PC Sol. Actual Current
Line PC Sol. CKT Status
Line PC Sol. Duty Cycle
Line PC Sol. Ref. Current
Shift PC Sol. Actual Current
Shift PC Sol. CKT Status
Shift PC Sol. Duty Cycle
Shift PC Sol. Ref. Current
Data List
F0, F1, F2
F0
F0, F1, F2
F0, F1, F2, F3
F0
F0, F1, F2
F0, F1, F2
F0, F1, F2
F0, F1, F2, F3
F0, F2, F3
Good, Flare, Tie-Up, Short,
F2
Good, Flare, Tie-Up, Short,
F2
Good, Flare, Tie-Up, Short,
F2
Good, Flare, Tie-Up, Short,
F2
Good, Flare, Tie-Up, Short,
F2
Good, Flare, Tie-Up, Short,
F2
Good, Flare, Tie-Up, Short,
F2
Good, Flare, Tie-Up, Short,
F2
Good, Flare, Tie-Up, Short,
F2
Good, Flare, Tie-Up, Short,
F2
F0, F3
OK, Open/Short to Volts,
F0, F3
F0, F2, F3
F0, F3
F0, F3
OK, Open/Short to Volts,
F0, F3
F0, F2, F3
F0, F3
Automatic Transmission:
Units Displayed
percent
volts
Applied, Released
1, 2, 3, 4, 5
Enabled, Disabled
°C (°F)
RPM
N⋅m (lb ft)
Ratio
Volts
Long, Inconclusive
Long, Inconclusive
Long, Inconclusive
Long, Inconclusive
Long, Inconclusive
Long, Inconclusive
Long, Inconclusive
Long, Inconclusive
Long, Inconclusive
Long, Inconclusive
amps
Short to GND
percent
amps
amps
Short to GND
percent
amps
5A-109
Typical Data Value
0
12.8
Released
1
Disabled
85-105°C (185-220°F)
660-680
0
7.97:1
12.6-14.0
Inconclusive, Good
Inconclusive, Good
Inconclusive, Good
Inconclusive, Good
Inconclusive, Good
Inconclusive, Good
Inconclusive, Good
Inconclusive, Good
Inconclusive, Good
Inconclusive, Good
0.96
OK
59
1.0
0.66
OK
39
0.66