7A-58 Heating, Ventilation and Air Conditioning:
Step
Inspect the air temperature sensor for the following
conditions.
• An obstruction to the airflow
9
• A damaged or a missing seal to the sensor
• Misaligned air ducts
• A misaligned sensor
Did you find and correct the condition?
1. Install a thermometer near the air temperature
sensor.
2. With a scan tool, observe the Duct Temp data
10
parameters in the HVAC Module Sensors Data list.
Does the scan tool indicate that the sensor
temperatures are within the specification at the
thermometer temperatures?
Test the temperature sensor resistance. Refer to
"Sensor Resistance Table (Volts to Temp to
11
Resistance)"
Does the resistance measure near the Sensor
Resistance Table value?
Inspect for poor connections at the harness connector
of the auxiliary HVAC control module. Refer to "Testing
12
for Intermittent Conditions and Poor Connections: " and
"Connector Repairs: ".
Did you find and correct the condition?
Inspect for poor connections at the harness connector
of the upper duct temp sensor, and lower duct temp
13
sensor. Refer to "Testing for Intermittent Conditions and
Poor Connections: " and "Connector Repairs: ".
Did you find and correct the condition?
Inspect for poor connections at the harness connector
of the HVAC control module. Refer to "Testing for
14
Intermittent Conditions and Poor Connections: " and
"Connector Repairs: ".
Did you find and correct the condition?
Replace the upper duct temp sensor or lower duct temp
sensor. Refer to "Air Temperature Sensor Replacement
15
- Upper", or "Air Temperature Sensor Replacement -
Lower".
Did you complete the replacement?
Replace the auxiliary HVAC control module. Refer to
"Auxiliary Heater and Air Conditioning Control
16
Replacement" for replacement, setup, and
programming.
Did you complete the replacement?
Replace the HVAC control module. Refer to "HVAC
Control Assembly Replacement" for replacement,
17
setup, and programming.
Did you complete the replacement?
Operate the system in order to verify the repair.
18
Did you correct the condition?
Action
Values
Yes
Go to Step 18
−3 to +3°C (−5
Go to Step 18
to +5°F)
Go to Step 15
Go to Step 18
Go to Step 18
Go to Step 18
Go to Step 18
Go to Step 18
Go to Step 18
System OK
No
Go to Step 10
Go to Step 10
Go to Step 13
Go to Step 16
Go to Step 15
Go to Step 17
Go to Step 2