5. Install the evaporator outlet hose to the compressor
hose.
6. Install the evaporator outlet hose nut to the
evaporator outlet hose.
Tightening torque
Tighten the nut to 20 N⋅m (15 lb ft).
7. Recharge the A/C system. Refer to "Refrigerant
Recovery and Recharging".
8. Test the affected A/C joints for leaks using J 39400-
A.
Air Conditioning Refrigerant Service Valve
Core Replacement
Special tool
J 39400-A Halogen Leak Detector
J 46246 Valve Core Removal Tool
Removal Procedure
1. Recover the refrigerant. Refer to "Refrigerant
Recovery and Recharging".
Heating, Ventilation and Air Conditioning:
2. Use J 46246 or equivalent to remove the valve core.
Installation Procedure
1. Use J 46246 or equivalent to install and tighten the
valve core.
2. Evacuate and charge the A/C system. Refer to
"Refrigerant Recovery and Recharging".
NOTE
To prevent loss of refrigerant charge, tighten
the cap. Replace the cap if the seal is missing
or damaged.
3. Test the affected A/C fittings for leaks using J 39400-
A.
7A-99