5A-296 Automatic Transmission:
10. Install the lube fluid pipe retainer (805) and the M6 x
1.0 x 14 mm lube fluid pipe retainer bolt (806) into
the torque converter housing assembly.
Tightening torque
Tighten the bolt to 5 N⋅m (44 lb in).
11. Install the fluid baffle (830) and the 2 - M6 x 1.0 x 12
mm fluid baffle bolts (829) M6 x 1.0 x 12 mm.
Tightening torque
Tighten the 2 transmission fluid baffle bolts to 5
N⋅m (44 lb in).
Reference: "Torque Converter Housing Installation".
Torque Converter Housing Installation
Reference: "Torque Converter Housing Cleaning and
Inspection".
1. Remove the case fluid passage seal (89).
2. Install a NEW case fluid passage seal (89) into the
transmission case assembly.
3. Apply a 3 mm (1/8 in) bead of sealant GM P/N
89020326 (Canadian P/N 89021188) on the inside of
the bolt holes of the scaling flange of the torque
converter housing assembly.
4. Remove the holding fixture bolt (1) to allow
clearance to install the torque converter housing
assembly.
5. Install the torque converter housing assembly to the
transmission case assembly.
6. Apply threadlocker GM P/N 12345382 (Canadian P/
N 10953499), to the threads of all the torque
converter housing bolts.
7. Install the 11 - M8 x 1.25 x 30 mm bolts (4) and hand
tighten.
8. Install the 2 - M8 x 1.25 x 30 mm bolt/studs (3) and
hand tighten.
9. Install the 2 - M8 x 1.25 x 35 mm bolts (6) and hand
tighten.
10. Install the 1 - M8 x 1.25 x 45 mm bolt (7) and hand
tighten.
11. Install the 1 - M8 x 1.25 x 30 mm TORX 40 bolt (8)
and hand tighten.