Suzuki XL7 2007 Service Manual page 1876

Jc636
Hide thumbs Also See for XL7 2007:
Table of Contents

Advertisement

7A-62 Heating, Ventilation and Air Conditioning:
Step
Connect a test lamp between the auxiliary mode actuator supply
voltage circuit and the low reference circuit of the auxiliary mode
7
actuator.
Does the test lamp illuminate?
1. Measure the voltage from the auxiliary mode door control
circuit to a good ground.
2. Place the auxiliary mode switch in each mode position. Refer
8
to Test Description.
Does the voltage measure near the specified values for each
mode selected?
Test the auxiliary mode actuator supply voltage circuit for an
open, short to ground or high resistance. Refer to "Circuit Testing:
9
" and "Wiring Repairs: ".
Did you find and correct the condition?
Test the low reference circuit of the auxiliary mode actuator for an
open or high resistance. Refer to "Circuit Testing: " and "Wiring
10
Repairs: ".
Did you find and correct the condition?
Test the auxiliary mode door control circuit for the following:
• An open
• A short to ground
11
• A short to voltage
Refer to "Circuit Testing: " and "Wiring Repairs: ".
Did you find and correct the condition?
Inspect the auxiliary mode door and the auxiliary mode actuator
for the following conditions:
• A misaligned auxiliary mode actuator. Refer to "Auxiliary Mode
Actuator Replacement".
• Broken or binding linkages or auxiliary mode door
12
• An obstruction that prevents the door from operating within its
full range of motion
• Missing seals to the auxiliary mode door
• Misaligned seals to the auxiliary mode door
Did you find and correct the condition?
Inspect for poor connections at the harness connector of the
auxiliary mode actuator. Refer to "Testing for Intermittent
13
Conditions and Poor Connections: " and "Connector Repairs: ".
Did you find and correct the condition?
Inspect for poor connections at the harness connector of the
auxiliary HVAC control module. Refer to "Testing for Intermittent
14
Conditions and Poor Connections: " and "Connector Repairs: ".
Did you find and correct the condition?
Replace the auxiliary mode actuator. Refer to "Auxiliary Mode
15
Actuator Replacement".
Did you complete the replacement?
Replace the auxiliary HVAC control module. Refer to "Control
16
Module References: " for replacement, setup, and programming.
Did you complete the replacement?
Operate the system in order to verify the repair.
17
Did you correct the condition?
Action
Yes
Go to Step 8
Go to Step 10
Go to Step 12
Go to Step 11
Go to Step 17
Go to Step 14
Go to Step 17
Go to Step 14
Go to Step 17
Go to Step 14
Go to Step 17
Go to Step 13
Go to Step 17
Go to Step 15
Go to Step 17
Go to Step 16
Go to Step 17
Go to Step 17
System OK
Go to Step 2
No

Advertisement