Suzuki XL7 2007 Service Manual page 1915

Jc636
Hide thumbs Also See for XL7 2007:
Table of Contents

Advertisement

CAUTION
!
Refer to "Fastener Notice: ".
5. Install the lower receiver dehydrator bolt to the
condenser.
Tightening torque
Tighten the bolt to 6.5 N⋅m (58 lb in).
6. Install the receiver dehydrator mounting clamp to the
condenser.
7. Install the receiver dehydrator mounting clamp bolt
to the condenser.
Tightening torque
Tighten the bolt to 4.2 N⋅m (37 lb in).
8. Install the front bumper fascia. Refer to "Front
Bumper Fascia Replacement: ".
9. Evacuate and charge the A/C system. Refer to
"Refrigerant Recovery and Recharging".
10. Test the affected A/C joints for leaks using J 39400-
A.
Heating, Ventilation and Air Conditioning:
Thermal Expansion Valve Replacement
Special tool
J 39400-A Halogen Leak Detector
1. Recover the refrigerant. Refer to "Refrigerant
Recovery and Recharging".
NOTE
When removing the thermal expansion valve
(TXV), keep dirt and foreign material from
getting on or into the sealing surfaces. Clean
tools and a clean work area are important for
proper service. The TXV seal area should be
cleaned before any repairs are performed.
The parts must be kept clean at all times and
any parts to be assembled should be cleaned
with a non-petroleum based solvent and
dried with air. Use only lint free cloths to wipe
parts. Do not allow solvent to enter
evaporator or hoses.
2. Remove the evaporator outlet hose and liquid line
retainer plate nut from the TXV.
3. Remove the evaporator outlet hose and liquid line
from the TXV.
4. Remove and discard the sealing washers from the
evaporator outlet hose and liquid line.
5. Install protective caps to the evaporator outlet hose
and the liquid line to prevent contamination and
desiccant saturation. Refer to "Sealing Washer
Replacement".
7A-101

Advertisement

Table of Contents
loading