Recording Functions - YOKOGAWA MuR10000 Manual

Table of Contents

Advertisement

Item
Moving average (dot model)
Integration time of the A/D converter
Temperature Unit
Alarm functions
Item
Alarms for each channel
Delay high limit alarm/delay low limit alarm
High limit on rate-of-change alarm/low limit on rate-of-change alarm
Use the alarm ACK operation
Set a hysteresis on the alarm occurrence/release value of high limit alarm and low limit alarm
Change the alarm output relay operation
Diagnosis output

Recording functions

Item
Chart speed
Turn trend recording ON/OFF (dot model)
Change the recording color of measurement channels (dot model).
Record by compensating for the pen offset along the time axis (pen model)
Record by setting recording zone
Partial expanded recording Use Partial in Basic Setting mode and select Use or Not.
IM 04P01B01-01E
Description
Use Moving_AVE in Basic Setting mode and select Use or Not.
If Use is selected, set the number of samples of moving average using Aux >
Moving_AVE in Setting mode.
If Not is selected, the Aux > Moving_AVE item does not appear.
Use A/D in Basic Setting mode to set the integration time of the A/D converter.
Select the temperature unit using Temperature in Basic Setting mode.
Description
Use Alarm in Setting mode.
• Alarm type
Use Personalize > Add function > Alarm delay in Basic Mode and select Use or
Not.
If Use is selected, delay high limit alarm (T) and delay low limit alarm (t) become
selectable under Alarm > Type in Setting mode.
If Not is selected, alarm delay cannot be selected.
• Alarm delay time
Use Aux > Alm delay T in Setting mode to set the alarm delay time.
Use Alarm in Setting mode and set the channel to rate-of-change alarm.
Use Alarm > Increase in Basic Setting mode to set the interval of the high limit on
rate-of-change alarm; use Alarm > Decrease in Basic Setting mode to set the interval
of the low limit on rate-of-change alarm.
• Relay operation and display operation
Set Alarm > Behavior in Basic Setting mode to Hold and set Alarm > Indicator to
Hold.
• Executing the alarm ACK operation
Use Func > Alarm ACK in Operation mode to execute the release of the alarm
output.
Use Alarm > Hysteresis in Basic Setting mode to set the hysteresis to be applied to
the high limit alarm and low limit alarm of measurement channels.
Likewise, use Alarm > M_Hysteresis to set the hysteresis to be applied to the high
limit alarm and low limit alarm of computation channels (/M1 option).
If Alarm > Act in Basic Setting mode set to De_energize, alarm output relay is
energized during normal operation and de-energized when an alarm occurs.
Use Alarm > Diagnosis in Basic Setting mode to set the function.
Description
Use Chart in Setting mode to set the chart speed.
Use Aux > Print out in Setting mode to set whether to trend record on each
measurement channel.
Use Color in Basic Setting mode to set the recording color of measurement channels. 7.5
Use Aux > POC in Setting mode to turn On/Off offset compensation.
Use Aux > Zone in Setting mode to set the recording zone for each channel.
If Use is selected, set the display mode using Aux > Partial in Setting mode.
If Not is selected, the Aux > Partial item does not appear.
1.10 Function Setup Guide
Reference
Section
7.11
6.3
7.2
7.25
Reference
Section
5.2
7.15
5.2
6.10
5.2
7.1
7.1
3.12
7.1
7.1
7.1
Reference
Section
5.4
6.6
7.6
6.4
7.13
6.5
1-35
1
2
3
4
5
6
7
8
9
10
11
12
App
Index

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents