YOKOGAWA MuR10000 Manual page 245

Table of Contents

Advertisement

Item
Channel switching
interval
Bar graph display
Relationship between the digital display and bargraph
Scale
Alarm point mark
Bar graph display mode Selectable from the two modes below.
Flag display
Display channel
Scale
Channel alarm status display
Date/time and chart speed display
DI/DO status display
Multiple display (display in which different screens can be assigned to the top and bottom sections)
Tag display
Status display
System display
Batch name display
SD memory card status
display
Lights out
Skip
IM 04P01B01-01E
Specifications
The switching interval of displayed channels can be set to 1 s, 2 s, 3 s, 4 s, or 5 s.
Displays the measured value on a bargraph.
Displays the same channel on the digital display and bargraph. On the 2CH digital + 2CH bargraph
display, the top bargraph is the left digital display channel and the bottom graph is the right digital
display channel.
Displays 10 equally spaced scale marks.
For a channel set to delta computation, the alarm point marks of h and l are displayed. For all other
channels, the alarm point marks of H, L, T, and t are displayed.
• Blinks on the bargraph when an alarm occurs. Stops blinking when the alarm is released.
• Set the base point of the bargraph to the left or right of the recording span whichever is smaller in
value.
• Set the base point of the bargraph to the 50% position of the recording span.
Displays measured values using flags.
The flag can be turned ON/OFF for each channel.
Flag (If flags overlap, the channel with the smallest number is displayed on top)
Displays 10 equally spaced scale marks.
Lists the alarm status of all channels using the symbols below.
Symbol
Description
Alarm is not set.
Alarm is not occurring.
Channel
Alarm is occurring.
number
Displays the channel number when an alarm occurs and clears when the alarm is
released.
If the alarm indication is set to hold operation, the indicator blinks when an alarm
occurs. When alarm ACK operation is performed, the indicator turns ON (stop
blinking) or OFF.
Displays the date/time on the left and chart speed on the right.
The date display format can be selected. The format is common with the "Date printout format."
DI:Displays the ON/OFF state of the remote control input terminal (/R1 option).
DO:Displays the relay operation (active) of the alarm output terminal (/A1, /A2, or /A3 option).
8 display types (see page 12-7) can be assigned to the top and bottom sections of the display (VFD).
Displays 7-digit tags in place of channel numbers.
See the digital display and bar graph display sections.
Displays the status below. The display condition is the same as the status display under the main
display (see page 12-7).
Alarm and chart end (/F1 option)
Displays system information by switching screens every 3 seconds. The main displayed contents
are as follows:
Analog: Number of inputs
Option1, Option2: Options that are installed
Math: Number of computation channels
Periodic: Periodic printout interval
Interval: Trend recording interval (dot model)
POC: Pen offset compensation ON/OFF (pen model)
MAC address: MAC address
Version: Recorder version number (firmware version number)
Batch name: Batch number (up to 26 characters) and lot number (4 or 6 digit number, or none)
(/BT1 option)
Displays the SD memory card status, usage, free space, capacity, volume label, and the remaining
length of time for saving data.
Displays nothing.
Skips the screen during screen switching.
12.4 Display Function Specifications
1
2
3
4
5
6
7
8
9
10
11
12
App
Index
12-9