1.10 Function Setup Guide

Item
Date/Time setting
DST
Setting initialization
Measuring input functions
Item
Range and span of the TC, RTD, or DC voltage
1-5V
Scaling
Square Root Computation • Range, span, and scale
Unused channels
Bias
Burnout detection function (TC input and 1-5V input)
RJC of TC input
Filter (pen model)
1-34
This section explains the settings necessary to use various functions of the recorder.
Read the section corresponding to the function you wish to use.
Note
This section contains all the settings related to each item. If the desired setting is the same as
the default value, you do not have to set it.
Description
Use Clock in Setting mode.
Sets the date/time for switching between DST and standard time using Aux > DST in
Setting mode.
Use Initialize in Basic Setting mode to initialize the settings of Setting mode and Basic
Setting mode to their default values.
Description
Use Range in Setting mode.
• Range, span, and scale
Use Range in Setting mode.
• Unit
Use Unit in setting mode to set the unit after scaling.
• Low-cut
Use Personalize > Add function > 1-5V low-cut in Basic Setting mode and select
Use or Not.
If Use is selected, turn On/Off Low-cut using Range in Setting mode.
If Not is selected, the Low-cut item does not appear in the Range setting.
• Range, span, and scale
Use Range in Setting mode.
• Unit
Use Unit in setting mode to set the unit after scaling.
Use Range in Setting mode.
• Unit
Use Unit in setting mode to set the unit after scaling.
• Low-cut
Use Personalize > Add function > SQRT low-cut in Basic Setting mode and select
Use or Not.
If Use is selected, set the Low-cut point using Range in Setting mode.
If Not is selected, the Low-cut item does not appear in the Range setting.
Use Range > Skip in Setting mode to disable the trend recording (dot model) and
periodic printout of the target channel.
Use Personalize > Add function > Bias in Basic Setting mode and select Use or Not. 7.15
If Use is selected, set the bias value that is added to the input using Bias in Setting
mode. If Not is selected, the Bias item does not appear.
Use Burnout in Basic Setting mode to set the burnout detection function for each
channel.
Use RJC in Basic Setting mode to select whether to use the internal RJC function or an
external RJC function.
Use Filter in Basic Setting mode and select Use or Not.
If Use is selected, set the filter time constant using Aux > Filter in Setting mode.
If Not is selected, the Aux > Filter item does not appear.
Reference
Section
5.5
6.16
7.17
Reference
Section
5.1
5.1
5.3
7.15
5.1
5.1
5.3
5.1
5.3
7.15
5.1
5.1
6.12
7.3
7.4
7.12
6.2
IM 04P01B01-01E