4.3 Menu Structure, Settings, and List of Default Values
Setup Item
Language > Lang
Date format > Type
Temperature > Temp
Personalize > Add function > Bias
Personalize > Add function > SQRT low-cut -
Personalize > Add function > 1-5V low-cut -
Personalize > Add function > Alarm delay
Personalize > Add function > Calibration
Personalize > Time print > Alarm
Personalize > Time print > Message
Personalize > Time print > RCD On
Personalize > Time print > C.Speed
Setting initialization
Initialize > Mode
Initialize > Mode > Are you sure?
Remote (/R1 option)
Remote > Remote No.
Remote > Remote No. > No.
Math (/M1 option)
Math > Timer (TLOG) > Timer No.
Math > Timer (TLOG) > Mode
Math > Timer (TLOG) > Interval (Relative) -
Math > Timer (TLOG) > Interval (Absolute) -
Math > Timer (TLOG) > Ref. Time
Math > Timer (TLOG) > Reset
Math > Timer (TLOG) > Print
Math > Color > Channel
Math > Color > Color
Math > Output pen > Pen ← CH
Math > Print2 > CH
Math > Print2 > Mode
Math > Print2 > SUM scale
Math > Bar graph > CH
Math > Bar graph > Graph
Math > Error data > Error
Math > Error data > Over
RS-422/485 (/C3 option)
RS-422/485 > Address
RS-422/485 > Baud rate
RS-422/485 > Data length
RS-422/485 > parity
RS-422/485 > Protocol
4-12
Pen/Dot
Selectable Range or Selections
-
English/Japanese/German/French
-
Y/M/D M/D/Y D/M/Y D.M.Y M.D.Y
-
°C/°F
-
Not/Use
Not/Use
Not/Use
-
Not/Use
-
Not/Use
-
HH:MM, HH:MM:SS, M/D H:M, M/D H:M:S,
YMD H:M:S
-
HH:MM, HH:MM:SS, M/D H:M, M/D H:M:S,
YMD H:M:S, None
-
HH:MM, HH:MM:SS, M/D H:M, M/D H:M:S,
YMD H:M:S
-
HH:MM, HH:MM:SS, M/D H:M, M/D H:M:S,
YMD H:M:S
-
Setup+Set/Set
-
No/Yes
-
1/2/3/4/5
-
Record On Off /Chart speed/Time adjust/
Math start stop (/M1)/Math reset (/M1)/
Manual print/Alarm ACK/Message1/Message2/
Message3/Message4/Message5/
Priority R_RCD (/BT1)/BatchCMT switch (/BT1)/
BatchCMT switch (/BT1)/Data save On/Off (/EM1)/
None
(/M1, /BT1, /EM1: option)
-
1/2
-
Off/Relative/Absolute
10 min to 24 h (1 min steps)
10min/12min/15min/20min/30min/1h/2h/3h/4h/6h/
8h/12h/24h
-
Hour 0 to 23 (1 hour steps)
-
On/Off
-
On/Off
Dot Model 0A/0B/0C/0D/0E/0F/0G/0J/0K/0M/0N/0P
Dot Model Purple/Red/Green/Blue/Brown/Black
Pen Model Pen: 1 to 4, Channel: 01 to 04/0A to 0J
-
0A/0B/0C/0D/0E/0F/0G/0J/0K/0M/0N/0P
-
AVE/MIX/SUM/MIN/MAX/INST
-
Off, /s, /min, /h, /day
-
0A/0B/0C/0D/0E/0F/0G/0J/0K/0M/0N/0P
-
Normal/Center
-
+Over/–Over
-
Skip/Limit
-
1 to 32
-
1200/2400/4800/9600/19200/38400
-
7/8
-
Odd/Even/None
-
NORMAL/MODBUS
Default Value
English
M.D.Y
°C
Not
Use
Not
Not
Use
HH:MM
HH:MM
HH:MM
HH:MM
Setup+Set
No
1
Record On/Off
1
Absolute
01:00
1h
00:00
On
On
0A
Purple: 0A/0G
Red: 0B/0J
Green: 0C/0K
Blue: 0D/0M
Brown: 0E/0N
Black: 0F/0P
1pen: 01, 2pen: 02,
3pen: 03, 4pen: 04,
0A
AVE
Off
0A
Normal
+Over
Skip
1
9600
8
Even
NORMAL
IM 04P01B01-01E