YOKOGAWA MuR10000 Manual page 57

Table of Contents

Advertisement

Remote control function (/R1 option)
Item
Description
Remote control function (/R1 option)
• Assign functions to the remote control input terminals
Use Remote in Basic Setting mode to set the function to be assigned to the remote control input
terminal.
• Secondary chart speed
If "chart speed switching" is assigned, use Aux > Chart 2 in Setting mode to set the secondary
chart speed.
• Switching between start printout and start printout 2 and between end printout and end printout
2 (/BT1 option)
If BatchCMT switch is assigned
Use Batch > Dual comment in Basic Setting mode to enable or disable start printout 2 and end
printout 2.
If Use is selected, set Batch > Detail > Start2 and End2 in Setting mode.
If Not is selected, the Batch > Detail > Start2 and End2 items in Setting mode do not appear.
Calibration Correction (/CC1 Option)
Item
Description
Calibration correction function
Use Personalize > Add function > Calibration in Basic Setting mode and select Use or Not.
If Use is selected,
• Use Calibration in Basic Setting mode to set the correction mode and the number of calibration
points.
• Use Calibration in Setting mode to set the measured value and correction value for each
channel.
If Not is selected, the Calibration item does not appear.
Header Printout (/BT1 Option)
Item
Description
Setting start printout and end printout
Use Batch in Basic Setting mode to set whether to use the start printout and end printout. If Use is
selected, select a Lot No. from 4 digits, 6 digits, or OFF.
If Use is selected,
Use Batch > Batch No. in Setting mode to set the batch number.
Use Batch > Lot No. in Setting mode to set the lot number.
Use Batch > Detail > Start, End in Setting mode.
If Not is selected, the Batch > Lot No. item in Basic Setting mode and the Batch item in Setting
mode do not appear.
Switch between start printout and start printout 2 and between end printout and end printout 2 (/R1 option)
• Switch settings
Assign "BatchCMT switch" to the remote control input terminal.
Use Batch > Dual comment in Basic Setting mode to set whether to use start printout 2 and end
printout 2.
If Use is selected, set Batch > Detail > Start2 and End2 in Setting mode.
If Not is selected, the Batch > Detail > Start2 and End2 items in Setting mode do not appear.
• Executing the switch
The switch occurs according to the status of the "BatchCMT switch" signal when "Record On/Off"
or "Priority R_RCD" signal assigned to the remote control input terminal rises or falls.
Printout of messages including measured/computed values
• Setting message strings
Use Aux > Message in Setting mode to enter the message to print out.
• Setting the message format
Use Batch > MSG format in Basic Setting mode and select whether to use the message format. 7.24
If Use is selected, use Batch > MSG format > Message No. in Setting mode to set the message
format.
If Not is selected, the Batch > MSG format item does not appear.
• Executing message printout
Use Func > Message in Operation mode to execute the message printout.
IM 04P01B01-01E
1.10 Function Setup Guide
Reference
Section
7.18
6.9
7.24
6.14
Reference
Section
7.15
7.23
6.13
Reference
Section
7.24
6.14
7.18
7.24
6.14
1.4
6.8
6.15
3.10
1-39
1
2
3
4
5
6
7
8
9
10
11
12
App
Index

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents