Dot Model
Date
Time
Channel data
Computation channel
Scale
Chart speed
Report start date/time
Report end date/time
Channel data
Computation channel
Scale
Chart speed
IM 04P01B01-01E
Appendix 1 Periodic Printout and Printout Using the TLOG Timer (/M1 Option)
Instantaneous Mode
Channel number
Measured
or tag
value
Mar.31.2004
15:50
TAG-001
1.000V
2
-1.000V
3
H-2.1050UNIT03
4
d
2.000V
TAG-00A
1UNIT0A
J
L
-1.00UNIT0J
0.000
TAG-001
50mm/h_
Time tick
• Date/Time
The date/time when the periodic printout was executed.
• Time tick
Indicates the position at the time the periodic printout was executed. If the time tick
cannot be printed correctly, it is not printed.
• Channel data, alarm, scale printout, and chart speed
These are the same as with the instantaneous mode of the pen model.
Report Mode
Channel number or tag
Range change occurrence mark
Measured value
Unit
Mar.31.2004 15:00
-Apr.01.2004 15:00*TPR
TAG-001*1.000V
2
-1.000V
3
-2.105500E+03UNIT03
4
2.000V
TAG-00A 1UNIT0A
C
*1.00
D
-10.00UNIT0D
150.00UNIT0D
100.00UNIT0D
E
1.0000%
J
-1.00UNIT0J
0.000
TAG-001
50mm/h_
Time tick
• Report start date/time and report end date/time
The start date/time and end date time of the report (statistical calculation) (periodic
printout interval).
• Time tick
This is the same as with the instantaneous mode.
• Event
This is the same as with the report mode of the pen model.
• Channel data
This is the same as with the report mode of the pen model. However, the channel
numbers are 1 to 6 or A to P.
• Scale and chart speed
These are the same as with the instantaneous mode of the pen model.
Prints the letter "d" for channels set to
delta computation.
Unit
Alarm
Event
2.000
V
Sum value
Min./Max./Ave.
2.000
V
Index
App-3
1
2
3
4
5
6
7
8
9
10
11
12