Setup Item
Ethernet (/C7 option)
Ethernet > Host > Host
Ethernet > Host > Domain
Ethernet > Local IP > A
Ethernet > Local IP > M
Ethernet > Local IP > G
Ethernet > DNS > DNS
Ethernet > DNS > P
Ethernet > DNS > S
Ethernet > DNS > Suffix_P
Ethernet > DNS > Suffix_S
Ethernet > Login > Login
Ethernet > LoginSet > Level
Ethernet > LoginSet > Register
Ethernet > LoginSet > User
Ethernet > LoginSet > Password
Ethernet > Timeout > Timeout
Ethernet > Timeout > Duration
Ethernet > K. Alive > Keep alive
Calibration (/CC1 option)
Calibration > CH
Calibration > Mode
Calibration > Point
Cust. menu > Cust. menu
Cust. menu > Password
Cust. menu > P_Adj
Select menu > Set mode > Range
Select menu > Set mode > Bias
Select menu > Set mode > Alarm
Select menu > Set mode > Unit
Select menu > Set mode > Chart speed
Select menu > Set mode > Aux
Select menu > Set mode > Calibration
Select menu > Set mode > Math
Select menu > Set mode > Batch name
Select menu > Set mode > Batch detail
Select menu > Function > Manual print
Select menu > Function > Setup list
Select menu > Function > Message
Select menu > Function > Buffer clear
Select menu > Function > Periodic
Select menu > Function > Data save
Select menu > Function > Data replay
Select menu > Function > SD eject
Batch (/BT1)
Batch > Batch
Batch > Lot No.
Batch > Dual comment
Batch > MSG format
SD memory card (/EM1 option)
Load param > File
Load param > Mode
Format > Label
Format > Execute
Adjustment
P_Adj > P_Adj
IM 04P01B01-01E
4.3 Menu Structure, Settings, and List of Default Values
Pen/Dot
Selectable Range or Selections
-
64 characters or less
-
64 characters or less
-
IP address
-
IP address (Subnet mask)
-
IP address (Default gateway)
-
On/Off
-
IP address (Primary DNS sever)
-
IP address (Secondary DNS sever)
-
Primary domain suffix
-
Secondary domain suffix
-
Use/Not
-
Admin/User1 to User6
-
On/Off
-
16 characters or less
-
4 characters or less
-
On/Off
-
1 to 120 min
-
On/Off
-
01 to 06
-
Revise Value, Abs. Value
-
2 to 16
-
Not/Use
-
Numbers and spaces within 4 digits
-
On/Off
-
On/Off
-
On/Off
-
On/Off
-
On/Off
-
On/Off
-
On/Off
-
On/Off
-
On/Off
-
On/Off
-
On/Off
-
On/Off
-
On/Off
-
On/Off
-
On/Off
-
On/Off
-
On/Off
Dot Model On/Off
-
On/Off
-
Not/Use
-
4/6/Not
-
Not/Use
-
Not/Use
-
Search text
-
Setup+Set/Setup
-
Up to 11 characters
-
Execute
Dot Model Hysteresis/Zero/Full
Pen Model Zero/Full
1
Default Value
Blank
Blank
2
0.0.0.0
0.0.0.0
0.0.0.0
Off
0.0.0.0
3
0.0.0.0
Blank
Blank
Not
4
Admin
Admin and User1
are On
Admin: admin
User1 to 6: user1
5
to user6
Administrator: 0
User1 to 6: 1 to 6
Off
6
1 min
On
01
Revise Value
7
2
Not
Blank
Off
8
On
On
On
On
On
9
On
On
On
On
10
On
On
On
On
On
11
On
On
On
On
12
Not
4
Not
Not
App
-
Setup+Set
-
Index
Execute
Hysteresis
Zero
4-13