YOKOGAWA MuR10000 Manual page 141

Table of Contents

Advertisement

IM 04P01B01-01E
MSG format
Choose a message format. Measured values,* message strings, and date/time can be
set arbitrarily.
13:H:M L16
CHR:Date/Time
CHARACTER key
Example: Based on the message 1 string of the standard function, you can set a
combination with message format 1 and print it out as message 1 including
measured values.*
Standard function
Process-1°C
Message 1
string:
result: 06/30
Message 1 printout
M/D H:M L09 01L02
Message format
1:
* Computed values can also be included on models with the /M1 option.
• Date/Time Format and Number of Characters Used
H:M
(Hour:Minute)
H:M:S
(Hour:Minute:Second)
M/D H:M
(Month/Day Hour:Minute)
M/D H:M:S
(Month/Day Hour:Minute:Second)
D/M H:M
(Day/Month Hour:Minute)
D/M H:M:S
(Day/Month Hour:Minute:Second)
D.M H:M
(Day.Month Hour:Minute)
D.M H:M:S
(Day.Month Hour:Minute:Second)
M.D H:M
(Month.Day Hour:Minute)
M.D H:M:S
(Month.Day Hour:Minute:Second)
Y/M/D H:M:S
(Year/Month/Day Hour:Minute:Second)
M/D/Y H:M:S
(Month/Day/Year Hour:Minute:Second)
D/M/Y H:M:S
(Day/Month/Year Hour:Minute:Second)
D.M.Y H:M:S
(Day.Month.Year Hour:Minute:Second)
M.D.Y H:M:S
(Month.Day.Year Hour:Minute:Second)
• Format of Measured Values and Computed Values, and Number of
Characters Used
• The format for measured values is 01, 02, ...06 (depending on the model). No units
are added. 7 characters are used.
• The format for computed (/M1 option) values is: 0A, 0B, 0C, 0D, 0E, 0F, 0G, 0J, 0K,
0M, 0N, and 0P (depending on the model). No units are added. 9 characters are
used.
• Character String Format
The format for message strings is L01 (1 character), L02 (2 characters), .... L16 (16
characters).
In the example above, L09 specifies "Process-1" and L02 specifies "°C ."
<Related Topics> Enabling the message format: Section 7.24
6.15 Setting the Message Format (/BT1 Option)
Comment
CHR:01...
Measured value
CHR:0A...
Computed value (/M1 option)
CHR:L01...
Message string (number of characters)
CHR:Date/Time
Date/Time
:
10:10
Process-1
134.8°C
10th and 11th character of the
message string (9 characters
already used, so this represents
the next characters)
Measured value on CH1 (no units)
Space
1-9th characters of the message string
Space (number of characters: 1)
Date/time
5 characters
8 characters
11 characters
14 characters
11 characters
14 characters
11 characters
14 characters
12 characters
15 characters
19 characters
19 characters
19 characters
19 characters
20 characters
App
Index
6-21
1
2
3
4
5
6
7
8
9
10
11
12

Hide quick links:

Advertisement

Table of Contents
loading