YOKOGAWA MuR10000 Manual page 246

Table of Contents

Advertisement

12.4 Display Function Specifications
Name
1CH digital display
2CH digital display
4CH digital display
6CH digital display
(Dot model)
1CH digital + 1CH bargraph
display
2CH digital + 2CH bargraph
display
1CH digital + 4CH bargraph
display (Pen model)
4CH bargraph display
(Pen model)
6CH bargraph display
(Dot model)
Flag display
Channel alarm status display
Time/Chart speed display
12-10
Display Example
Measurement channel
1H3000.0ABC
Alarm
Measured
Channel number
value
Computation channel
AH9999999.9
Measurement channel
1H-1999.9ABCDEF
2L 2000.0PQRSTU
Computation channel
AH-999999.9ABCDEF
BL9999999.9PQRSTU
1H3000.0 1H3000.0
3H3000.0 4H3000.0
Computation channel
AH-1999.9 BH-1999.9
CH9999.9 DH9999.9
999.9 999.9 999.9
999.9 999.9 999.9
1H3000.0ABC
1H3000.0 2L-999.9
Computation channel
AH-1999.9 BH9999.9
1H-1999.9ABCDEF
Computation channel
AH9999999.9ABCDEF
Sep.21.2004 1200
11:26:37
Channel number (1 digit), alarm (1 digit),
measured value (6 digits), unit (3 digits)
Displays using 5 х 7 dots when the unit
Unit
exceeds 3 digits.
Channel number (1 digit), alarm (1 digit),
computed value (9 digits)
Channel number (1 digit), alarm (1 digit),
measured value (7 digits), unit (6 digits)
Channel number (1 digit), alarm (1 digit),
computed value (9 digits), unit (6 digits)
Channel number (1 digit), alarm (1 digit),
measured value (6 digits)
Channel number (1 digit), alarm (1 digit),
computed value (6 digits)
Displayable values are –19999 to 99999 and
a decimal. If this range is exceeded, the value
is displayed as"–####" or "+####."
Measured value (5 or 6 digits)
Channel number (1 digit), alarm (1 digit),
measured value (6 digits), unit (3 digits)
Bar graph, scale, alarm (bar graph)
Value and bar graph of the same channel.
Channel number (1 digit), alarm (1 digit),
measured value (6 digits)
Bar graph, scale
Channel number (1 digit), alarm (1 digit),
computed value (6 digits)
Bar graph, scale
Displayable values are –19999 to 99999 and a
decimal. If this range is exceeded, the value
is displayed as"–####" or "+####."
Channel number (1 digit), alarm (1 digit),
measured value (7 digits), unit (6 digits)
Channel number (1 digit), alarm (1 digit),
computed value (9 digits), unit (6 digits)
Bar graph, scale
Bar graph, scale
Flag, scale
Channel number
Displays the date/time on the left and chart
speed on the right.
mm/h
Description
Alarm is not set.
Alarm is not occurring.
Alarm is occurring.
IM 04P01B01-01E

Hide quick links:

Advertisement

Table of Contents
loading