Appendix 2 Login Procedure; When Using The Login Function - YOKOGAWA GX10 User Manual

Gx series; gp series; gm series; smartdac+ communication command
Hide thumbs Also See for GX10:
Table of Contents

Advertisement

Appendix 2 Login Procedure

When Using the Login Function

App-2
To communicate using the general communication feature, you must log in to the recorder
from your PC. If you complete the procedure successfully up to "Login complete" in the
following figure, you will be able to use the commands.
No
Within the number
E1: 732
of connections?
Disconnect
Receive command
Log in with the CLogin command
**
Verification match?
Login complete
Start
End
Judge
E1: 401
Response from the recorder (message omitted)
Code
Response
* "E1:402" is returned when the advanced security function (/AS) is enabled.
** E251. If the format of the CLogin command is not correct, verification is not performed,
and an error code indicating the error is returned.
The following error code is returned when the advanced security function (/AS) is
enabled.
251, 262, 263, 264, 265, 272, 273, 767
When the password management is in use, the following error code is returned in addition
to the error code above.
004,252,261,651,657,760,761,762,763,764,765,766,768,769,770,771,772,773,774,775
Connect
*
E1: 401
E0
For Bluetooth, the Bluetooth connection flow
chart is inserted here (see appendix 7).
IM 04L51B01-17EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gm10Gx20Gp20Gp10

Table of Contents