Appendix 2 Login Procedure
When Using the Login Function
App-2
To communicate using the general communication feature, you must log in to the recorder
from your PC. If you complete the procedure successfully up to "Login complete" in the
following figure, you will be able to use the commands.
No
Within the number
E1: 732
of connections?
Disconnect
Receive command
Log in with the CLogin command
**
Verification match?
Login complete
Start
End
Judge
E1: 401
Response from the recorder (message omitted)
Code
Response
* "E1:402" is returned when the advanced security function (/AS) is enabled.
** E251. If the format of the CLogin command is not correct, verification is not performed,
and an error code indicating the error is returned.
The following error code is returned when the advanced security function (/AS) is
enabled.
251, 262, 263, 264, 265, 272, 273, 767
When the password management is in use, the following error code is returned in addition
to the error code above.
004,252,261,651,657,760,761,762,763,764,765,766,768,769,770,771,772,773,774,775
Connect
*
E1: 401
E0
For Bluetooth, the Bluetooth connection flow
chart is inserted here (see appendix 7).
IM 04L51B01-17EN