SRCFINTK Fine Tracking Adjust

SRCFINTK Fine Tracking Adjust
Syntax
Figure 7-249
SRCFINTK Syntax
Description
The SRCFINTK command controls the fine adjustment of the frequency
of the built-in tracking-generator oscillator. Once enabled, this
adjustment is made in digital-to-analog-converter (DAC) values from 0
to 255. For coarse adjustment, refer to the SRCCRSTK command
description. SRCFINTK is available only with an 8560E/EC Option
002.
Parameters
number
UP or DN
Preset State
128
602
integer from 0 to 255.