Gp Gate Polarity; Figure 7-130 Gp Syntax; Figure 7-131 Gp Query Response - Agilent Technologies 8560E User Manual

Agilent technologies 8560 e-series and ec-series spectrum analyzers
Table of Contents

Advertisement

Language Reference

GP Gate Polarity

GP Gate Polarity
Syntax
Figure 7-130
GP Syntax
Description
The GP command sets the polarity (positive or negative) for the gate
trigger. If the gate control (GATECTL) is in the edge mode, the gate
delay timer can be triggered on either a positive or negative edge of the
trigger input. If the gate control is in level mode and positive is chosen,
the gate will be on when the trigger input is high. If the gate control is
in level mode and negative is chosen, the gate will be on when the
trigger input is low.
Preset State
Positive
Query Response
Figure 7-131
GP Query Response
Example
OUTPUT 718;"GP POS;"
486
Chapter 7