MKSS Marker to Center Frequency Step-Size

Syntax
Figure 7-184
MKSS Syntax
Description
The MKSS command sets the center frequency step-size equal to the
frequency value of the active marker.
Example
10
s$
20
30
40
50
60
70
80
"
90
100
Chapter 7
INPUT "CONNECT THE 300 MHZ CALIBRATOR TO THE INPUT",An
OUTPUT 718;"IP;SNGLS;CF 300MHZ;SP 20MHZ;TS;"
OUTPUT 718;"MKPK HI;MKSS;MKD;CF UP;TS;MKPK HI;"
OUTPUT 718;"MKA?;"
ENTER 718;Delta_amplitude
OUTPUT 718;"MKF?;"
ENTER 718;Delta_freq
PRINT "DIFFERENCE IN AMPLITUDE IS",Delta_amplitude,"DB
PRINT "DIFFERENCE IN FREQUENCY IS ",Delta_freq,"HZ"