Query Response
Figure 7-250
SRCFINTK Query Response
Example
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
RE."
200
210
220
230
240
250
260
270
280
290
300
310
Chapter 7
OUTPUT 718;"IP;"
OUTPUT 718;"FA 300KHZ;FB 1GHZ;"
OUTPUT 718;"SRCPWR ON;"
OUTPUT 718;"SWPCPL SR;RB 10KHZ;"
OUTPUT 718;"TS;DONE?;"
ENTER 718;Done
OUTPUT 718;"SRCCRSTK EP;"
PRINT "ADJUST TRACKING (coarse adjust) USING KNOB ON
ANALYZER."
PRINT "PRESS [HOLD], THEN CONTINUE WHEN READY."
PAUSE
OUTPUT 718;"TS;DONE?;"
ENTER 718;Done
OUTPUT 718;"SRCFINTK EP;"
PRINT "ADJUST TRACKING (fine adjust) USING KNOB ON
ANALYZER."
PRINT "PRESS [HOLD], THEN CONTINUE WHEN READY."
PAUSE
OUTPUT 718;"TS;DONE?;"
ENTER 718;Done
PRINT "CONNECT THRU.
PAUSE
OUTPUT 718;"STORETHRU;"
OUTPUT 718;"TS;DONE?;"
ENTER 718;Done
OUTPUT 718;"NORMLIZE ON;"
OUTPUT 718;"TS;DONE?;"
ENTER 718;Done
OUTPUT 718;"NRPOS 8;TS;"
PRINT "RECONNECT DUT.
PAUSE
LOCAL 718
END