Panasonic MINAS A5 Series Operating Instructions Manual page 92

Ac servo motor & driver
Hide thumbs Also See for MINAS A5 Series:
Table of Contents

Advertisement

2
Preparation
Connecting Example of H-frame
plate from the power source.
Symmetric current should be 5000 Arms or below.
If the short-circuit current on the power source
exceeds this value, use a current-limiting device
(e.g. current-limiting fuse, current-limiting circuit
breaker or transformer).
To protect power supply line from overloading,
install a wiring circuit breaker rated to the capacity
of the power supply.
Removes external noise from the power lines. And
reduces an effect of the noise generated by the
servo driver.
Turns on/off the main power of the servo driver.
Use coil surge suppression units together with this.
(to be supplied by customer)
Reduces harmonic current of the main power.
(
to be supplied by
)
customer
* Use a power
supply with
5 A or larger
capacity.
(optional)
resistor,
.
regenerative resistor (Option).
Diagram" on P.2-47.
Note
application. The wiring indicated with the broken line shall be provided only when required.
Related page
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
2-44
2.
Overall Wiring (H-frame, 400 V type)
-
Residual
current device
L1 L2 L3
P.2-46
B1
B2
(
to be supplied by
customer
.
"Dynamic Brake" on P.2-67.
Mains
* Use a power
supply with
5 A or larger
capacity.
L1C
0V
24V
Turns on/off the dynamic brake
resistor.
Use coil surge suppression units
)
together with this.
(to be supplied by customer)
Charge lamp (LED)
Do not make displacement,
wiring or inspection while
the LED is lit - cause of
electric shock.
P.2-46
P.2-46

Hide quick links:

Advertisement

Table of Contents
loading