Panasonic MINAS A5 Series Operating Instructions Manual page 252

Ac servo motor & driver
Hide thumbs Also See for MINAS A5 Series:
Table of Contents

Advertisement

1. Details of parameter
[Class 4] I/F monitor setting
Pr4.16
Type of analog monitor 1
Select the type of monitor for analog monitor 1. *
Pr4.17
Analog monitor 1 output gain
Set up the output gain of analog monitor 1.
Pr4.18
Type of analog monitor 2
Select the type of monitor for analog monitor 2. *
Pr4.19
Analog monitor 2 output gain
Set up the output gain of analog monitor 2.
Pr4.20
Type of digital monitor
Select type of the digital monitor.
Setup value
[0]
1
2
3
Note
Related page
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
4-36
Type of monitor
Positioning complete condition
Positional command
Gain selected
Range
0 to 21
Range
[Monitor unit
0 to 214748364
in Pr4.16] / V
Range
0 to 21
Range
[Monitor unit
0 to 214748364
in Pr4.16] / V
Range
0 to 3
Digital signal output
L output
1st gain
Pr0.00 Parameter No.
Class
* "
Related
Unit
Default
control mode
0
P S T F
Related
Unit
Default
control mode
0
P S T F
Related
Unit
Default
control mode
4
P S T F
Related
Unit
Default
control mode
0
P S T F
Related
Unit
Default
control mode
0
P S T F
H output
Completed
Generated
2nd gain