Panasonic MINAS A5 Series Operating Instructions Manual page 63

Ac servo motor & driver
Hide thumbs Also See for MINAS A5 Series:
Table of Contents

Advertisement

2
Preparation
Compose the circuit so that the main circuit power will be shut off when an error occurs.
In Case of Single Phase, A to D-frame, 100 V / 200 V type
Power supply Single phase, 100V
Remarks
When you use single phase,
connect the main power
between L1 and L3 terminals.
Remove the short wire when you connect
the external regenerative resistor.
(C, D-Frame)
In Case of 3-Phase, A to D-frame, 200 V type
Power supply 3-phase, 200V
Remove the short wire when you connect
the external regenerative resistor.
(C, D-Frame)
Note
The wiring indicated with the broken line shall be provided only when required.
Related page
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
2.
Wiring Diagram (A to D-frame, 100/200 V type)
–15%
to 120V
MCCB
External regenerative resistor
Red
White
* These colors
Black
are used for
Green or Green/Yellow
optional cable.
Motor
Insulated
+
DC12 to 24V
(±5%)
–15%
to 240V
+10%
MCCB
External regenerative resistor
Red
White
* These colors
Black
are used for
Green or Green/Yellow
optional cable.
Motor
Insulated
+
DC12 to 24V
(±5%)
+10%
Single phase, 200V
ALM
ON
OFF
Coil surge suppression units
L
XA
L1
Main power
L2
supply
L3
L1C
Control power
MC
supply
L2C
XB
B1
B3
B2
U
Motor
V
connection
W
ALM
X4
37
ALM+
36
ALM
ON
OFF
Coil surge suppression units
L
XA
L1
Main power
L2
supply
L3
L1C
MC
Control power
supply
L2C
XB
B1
B3
B2
U
Motor
V
connection
W
ALM
X4
37
ALM+
36
–15%
to 240V
+10%
Built-in thermostat of
an external regenerative
MC
resistor (light yellow)
Built-in thermostat of
an external regenerative
MC
resistor (light yellow)
2-15
1
2
3
4
5
6
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents