2.
Overall Wiring (H-frame, 200 V type)
: High voltage
L1C
L2C
DB1
DB2
L1
L2
L3
B1
B2
NC
Ground
(earth)
Ground terminal
Motor cable (Shield wire)
Brake cable
DC Power supply
for brake DC24V
(to be supplied
by customer)
Note
• The figure above shows connections on velocity, position, torque and full-closed mode driver.
• Only for position control type is not provided.
Related page
• P.2-30 "Wiring of the Main Circuit (H-frame, 200 V type)"
• P.2-48 "Specifications of Motor connector"
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
P.2-60
X1
X2
X3
X4
X5
X6
CHARGE
U
V
W
Junction cable
for encoder
U
-phase
V
-phase
W
-phase
P.2-30
PC (to be supplied by customer)
Setup support software
"PANATERM"
Please download
from our web site.
or host controller
feedback scale
encoder
To connect these terminals to the primary
power supply (particularly, the 24 VDC
power supply for brake and the 24 VDC
power supply for regenerative resistor),
insulation is required.
Do not connect these terminals to the same
power supply.
resistor, connect the external regenerative
resistor between B1 and B2, set up Pr0.16
to 1 or 2.
resistor, connect the magnetic contactor (for
controlling) for external dynamic brake to
between LIC and DB1.
1