Panasonic MINAS A5 Series Operating Instructions Manual page 353

Ac servo motor & driver
Hide thumbs Also See for MINAS A5 Series:
Table of Contents

Advertisement

7
Supplement
Safety input signal
For list of connector pin numbers, refer to P.2-53,
Signal
Safety
input 1
Safety
input 2
<Response time>
Safety input 1 or 2 enables STO to operate: within 5 ms of response time, the motor
output torque will be turned off.
Caution
Safety output signal from the safety controller and safety sensor may include L pulse for
self-diagnosis.
To prevent the L pulse from mis-triggering STO function, the safety input circuit has
Therefore, if the off period of safety input signal less than 1 ms, the safety input circuit
Safety input
signal
Servo driver
Operate
Note
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
1. Safety function
Input & output signals
Symbol
Pin No.
Input 1 that triggers STO function. This input turns
SF1+
4
off the upper arm drive signal of power transistor.
When using the function, connect this pin in a way
so that the photocoupler of this input circuit turns off
3
to activate STO function.
Input 2 that triggers STO function. This input turns
SF2+
6
off the lower arm drive signal of power transistor.
When using the function, connect this pin in a way
so that the photocoupler of this input circuit turns off
5
to activate STO function.
L pulse for self-diagnosis
1 ms or shorter
Contents
5 ms or more
5 ms or shorter
Response time
STO state
1
2
Control
mode
Compatible
all control
mode
3
4
5
6
7
7-3