1. Details of parameter
[Class 5] Enhancing setting
Pr5.16 *
Alarm clear input setup
Setup value
[0]
1
Pr5.17
Counter clear input mode
You can set up the clearing conditions of the counter clear input signal.
Setup value
0
1
2
[3]
4
Note
Invalidation of command pulse inhibit
Pr5.18
input
Select command pulse inhibit input enable/disable.
Setup value
0
[1]
Command pulse inhibit input reading
Pr5.19 *
setup
Setup value
[0]
1
2
3
4
Caution
Longer reading period protects against operation error due to noise but decreases response
to input signal.
Note
Related page
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Recognition time
120ms
Clear condition
INH input
Valid
Signal reading period
0.166ms
0.333ms
1ms
1.666ms
Pr0.00 Parameter No.
Class
* "
Range
Unit
Default
0 to 1
Range
Unit
Default
0 to 4
Range
Unit
Default
0 to 1
Range
Unit
Default
0 to 4
1
Related
control mode
0
P S T F
2
Related
control mode
3
P
F
3
4
Related
control mode
1
P
F
5
Related
control mode
0
P
F
6
7
4-47