Panasonic MINAS A5 Series Operating Instructions Manual page 90

Ac servo motor & driver
Hide thumbs Also See for MINAS A5 Series:
Table of Contents

Advertisement

2
Preparation
G-frame, 400 V type
Never touch the terminal to which high voltage is applied. There is a risk of electric shock.
Tips on Wiring
2)Make wiring
Use clamp type terminals of round shape with insulation cover for wiring to the terminal
block. For cable diameter and size, reter to "Driver and List of Applicable Peripheral
Equipments" (P.2-11).
Tighten the terminal block screw with a torque between 2.0 and 2.4
1.0 and 1.7
Tighten the screw securing the cover with the torque written on P.2-11.
MCCB
Motor
DC
Varistor
The wiring indicated with the broken line shall be provided only when required.
Note
Related page
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
2-42
2.
Wiring of the Main Circuit (G-frame, 400 V type)
m (right side).
NC
DC
24V
24V
0V
L1
NC
MC
L
L2
NC
L3
DB1
DB2
B1
NC
B2
NC
NC
U
U
DB3
V
V
DB4
W
NC
W
E
24V
Never start/stop the motor with this Magnetic
Contactor.
Avoid shorting and grounding.
Don't connect the main power.
Earth-ground this.
Don't connect the earth cable to other inserting
slot, nor make them touch.
* Do not connect anything to NC.
m (left side) and
-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents