Panasonic MINAS A5 Series Operating Instructions Manual page 342

Ac servo motor & driver
Hide thumbs Also See for MINAS A5 Series:
Table of Contents

Advertisement

2. Setup of gain pre-adjustment protection
6) Setup of hybrid deviation excess error protection
At the initial operation with full-closed control, operation failure may occur due to re-
verse connection of external scale or wrong external scale division ratio.
sued when the deviation of motor position (encoder unit) and load position (external
scale unit) exceed Pr3.28 Setup of hybrid deviation excess.
tion varies with the operation speed and gain setup. Add a margin to this setting ac-
cording to your operating condition.
Related page
P.4-32 (Pr3.28)
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
-
-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents