2
Preparation
Compose the circuit so that the main circuit power will be shut off when an error occurs.
In Case of 3-Phase, H-frame, 200 V type
Power supply 3-phase, 200V
MCCB
Power supply
(3-phase)
Insulated
DC24V
Note 2)
Dynamic Brake resistor
Note 3)
Note 1)
Magnetic contactor MC2 must be the same as the contactor MC1 in the main circuit.
Note 2)
Servo may be turned on in the external sequence if the dynamic brake resistor deposits: to protect the
system, provide the auxiliary contact.
Note 3)
Use 1.2
, 400 W resistor (to be supplied by customer).
Note 4)
To use the external dynamic brake resistor:
Connect the R1 and R2 terminals to B1 and B2.
Connect the T1 and T2 terminals as shown in the left diagram.
Connect the 24 V and 0 V terminals to a 24 VDC power supply.
Connect the E terminal to the ground.
Refer to P.7-122 "Options" for the specifications of the external regenerative resistor.
Note 5)
Provide an external protective device (e.g. thermal fuse) to monitor the temperature of the external
dynamic brake resistor.
Note
The wiring indicated with the broken line shall be provided only when required.
Related page
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
2.
Wiring Diagram (H-frame, 200 V type)
–15%
to 230V
+10%
ON
L
MC1
+
External
regenerative resistor
Note 1)
Note 4)
MC2
Coil surge suppression units
Note 5) Note 5) Note 5)
MC2
Motor
Insulated
+
DC12 to 24V
(±5%)
Built-in thermostat of
an external regenerative resistor
MC1
(T1 and T2 terminals)
ALM
OFF
Coil surge suppression units
L1
Main power
L2
supply
L3
L1C
Control power
supply
L2C
B1
B2
NC
DB1
DB2
U
Motor
V
connection
W
ALM
37
ALM+
36
ALM−
1
2
3
4
5
6
7
2-31