15. How to Use the Front Panel
Monitor Mode (EXECUTION display)
(8) Alarm Display
alarm
No.
A0
Overload protection
Over-regeneration
A1
alarm
A2
Battery alarm
A3
Fan alarm
Encoder communication
A4
alarm
A5
Encoder overheat alarm
Oscillation detection
A6
alarm
A7
Lifetime detection alarm
External scale error
A8
alarm
External scale
A9
communication alarm
*1 Alarms can be cleared by using the alarm clear. Because the all existing alarms are kept cleared while the alarm
by using user parameter.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
2-98
......No alarm occurred
......High priority alarm
Alarm number
Alarm
Load factor is 85% or more the protection level.
Regenerative load factor is 85% or more the
protection level.
Battery voltage is 3.2 V or lower.
Fan has stopped for 1 sec.
The number of successive encoder communication
The encoder detects overheat alarm.
Oscillation or vibration is detected.
Life expectancy of capacitor or fan is short.
The external scale detects the alarm.
The number of successive external scale